Top Questions - Automatoes most recent 30 from http://automatoes.com 2010-09-05T22:57:23Z http://automatoes.com/feeds http://www.creativecommons.org/licenses/by-nc/2.5/rdf http://automatoes.com/questions/29/how-do-i-convert-the-4-hart-values-into-4-analog-signals-4-20ma How do I convert the 4 Hart values into 4 analog signals (4..20mA)? Roque Wendover 2010-03-14T10:32:37Z 2010-08-29T16:24:07Z <p>Guys,</p> <p>I have an instrument that sends all its values trought Hart. But my spare cards don't support Hart, only 4..20mA signals. Is there any converter for this?</p> <p>Best regards, Roque Wendover</p> http://automatoes.com/questions/37/is-there-any-difference-between-dcs-and-plc Is there any difference between DCS and PLC? John Doe 2010-03-23T00:26:34Z 2010-08-28T21:24:09Z <p>Folks,</p> <p>I'm a beginner in Automation world. </p> <p>Is there any difference between DCS and PLC?</p> <p>Thanks.</p> http://automatoes.com/questions/82/abb-xa-800-ai-895-crd ABB Xa 800 AI 895 Crd stokes10 2010-05-21T04:15:31Z 2010-08-28T21:24:09Z <p>Afternoon,</p> <p>I am experiencing a strange phenomenom configuring ANALOGUE OUTPUT CHANNELS on an AI895.</p> <p>-</p> <ul> <li>List item</li> </ul> <h2>I Have Created 3 Nunique Variables local to a project of the type RealIO.</h2> <p>I then connected the Variables at the IO card channels on channels 5 6 and 7 and activated the channels.(1-4 were already configured) -An instruments tecnician connected the feild device to channel5 and powered up.</p> <p>I noticed connection error 10 on Channel 5 however channel 6 was ok with nothing connected. I sent full range to the instrument and the technician stated that he was reading nothing on channel 5 and only on 6 ??</p> <ul> <li>List item</li> </ul> <p>in essence..I write to channel 5 in the software and the value goes to channel 6 on te cards terminals.</p> <p>write to channel 6 and the value goes to channel 7 on the actual card terminals. and so on.</p> <ul> <li>List item</li> </ul> <p>I have elimnated the base and the card by writing the same data to a different address at a new card.The same fault exists.</p> <ul> <li>List item</li> </ul> <p>I have also disconneted all associations with graphics.</p> <p>HAS ANY ONE COME ACROOS SUCH A FAULT BEFORE?????</p> http://automatoes.com/questions/79/plc-change-management-software-plc-version-control PLC Change Management Software - PLC Version Control Habbi Opin 2010-05-05T12:08:00Z 2010-08-25T15:24:22Z <p>Can you suggest a PLC Change Management Software with PLC Version Control feature?</p> http://automatoes.com/questions/40/what-is-winlc What is WinLC ? John Doe 2010-03-23T02:38:47Z 2010-08-24T09:24:14Z <p>Hi, </p> <p>today we had a meeting and they were saying about this WinLC. What is that? Is it some kind of SCADA system?</p> http://automatoes.com/questions/73/temperature-sensor-element-difference-between-rtd-and-thermocouple Temperature sensor element - difference between RTD and thermocouple ControlMan 2010-05-02T21:32:25Z 2010-08-23T02:24:05Z <p>Hello!</p> <p>what is the difference between RTD and thermocouple? Which one is more accurate?</p> <p>Thanks in advance.</p> http://automatoes.com/questions/81/wirelesshart-technology WirelessHart Technology Microwave 2010-05-07T02:12:23Z 2010-05-07T02:12:23Z <p>Have you heard that this technology is now industry standard for wireless communication? What do you think about this technology?</p> http://automatoes.com/questions/78/siemens-system-block-sfc20-blkmov-in-a-s7-400-system Siemens system block SFC20 "BLKMOV" in a S7-400 system PController 2010-05-04T22:51:42Z 2010-05-04T22:51:42Z <p>Hi,</p> <p>I need some help configuring the system block SFC20 "BLKMOV" in a S7-400 system. I want to copy DW 6 and 3 more words ,total 4 words, from DB100 to DB200. I want the first word from DB100 to end up in DW32 in DB200. There is a couple of ways to write the input parameters to the SFC20 that the S7 compiler think is OK, but I don't know which one that will do the trick. In the help text it says that both the SRCBLK &amp; the DSTBLK is "area", but if I want to copy between datablocks I can't define DSTBLK as area, only as the start of the area. Examples: This way I can declare both source and destination as area but I can't change datablock:</p> <pre><code> OPN DB100 CALL "BLKMOV" SRCBLK :=P#DBX 6.0 BYTE 8 RET_VAL:=#RetVal DSTBLK :=P#DBX 32.0 BYTE 8 </code></pre> <p>This way I can change datablock but the destination is then declared as the start of the destination area. What about this?</p> <pre><code> OPN DB100 CALL "BLKMOV" SRCBLK :=P#DBX 6.0 BYTE 8 RET_VAL:=#RetVal DSTBLK :=DB200.DBB32 </code></pre> http://automatoes.com/questions/33/how-does-an-earth-fault-monitor-work How does an earth fault monitor work? Roque Wendover 2010-03-14T19:56:19Z 2010-05-04T13:04:41Z <p>Hi, </p> <p>I have installed in the PLC panel a earth fault monitor. Always we have some grounding problem it gives an alarm. But I have no idea how it works. </p> <p>Does anyone knows its working principles?</p> <p>:)</p> http://automatoes.com/questions/67/which-are-the-fastest-plcs Which are the fastest PLCs Bernard Bernard 2010-05-02T14:50:56Z 2010-05-04T10:20:13Z <p>Srs,</p> <p>Automation is not properly my area of work. But I need to specify, or at least suggest some PLCs for our application. It needs very fast scan times. </p> <p>Could you suggest me starting points for that?</p> <p>Thanks in advance.</p> http://automatoes.com/questions/71/how-do-i-identify-a-cathode-or-an-anode-in-a-led How do I identify a Cathode or an Anode in a LED? Michael Dellan 2010-05-02T19:00:37Z 2010-05-02T20:16:48Z <p>Guys,</p> <p>I'm a engineering student, learning automation and electronics. Could you help me please identify a Cathode or an Anode in a LED? I don’t see any markings that could indicate this on the LED.</p> <p>Thank you again.</p> <p>Best regards, Michael</p> http://automatoes.com/questions/66/siemens-simatic-step-7-v5-4-for-download Siemens Simatic Step 7 V5.4 for download Lucius Romaom 2010-05-02T07:20:00Z 2010-05-02T18:43:19Z <p>Hi everyone,</p> <p>I had a course and the instructor told me that it is possible to download the Step 7 from Siemens site with a 14 days free license. But I couldn't find where the download link is.</p> <p>Is it possible to download Step 7 from Siemens, or this guy is crazy?</p> <p>Kind regards.</p> <p>Lucius</p> http://automatoes.com/questions/69/learning-about-stepper-and-servo-motors Learning about Stepper and Servo Motors Michael Dellan 2010-05-02T18:36:41Z 2010-05-02T18:36:41Z <p>Hello everybody,</p> <p>I'm a engineering student. I need good information on Servo and Stepper motors, do you have any good references, books, websites, etc?</p> <p>I will need them for a school project. I would appreciate any help. </p> <p>Thank you!</p> http://automatoes.com/questions/68/s7-mmc-micro-memory-card-corrupted S7 MMC Micro Memory Card Corrupted Lucius Romaom 2010-05-02T18:25:44Z 2010-05-02T18:25:44Z <p>Hi guys,</p> <p>I'm having a problem with the S7 300 CPU Memory Card. Somehow it corrupted, and it is not working anymore. The problem started after I did some downloads to the CPU. I tried to reset using two different procedures that I found on Siemens manuals, but with no luck.</p> <p>Looks like the Siemens File System is damaged, and I know that I cannot format it using a regular PC.</p> <p>Does it have any chance to recover it, or I have to buy a new one from Siemens?</p> <p>Thanks.</p> <p>Lucius</p> http://automatoes.com/questions/47/should-i-use-as-interface-asi-which-are-asi-characteristics Should I use AS-Interface (ASI)? Which are ASI characteristics? Sarah Skolberg 2010-03-24T16:52:36Z 2010-05-02T03:15:58Z <p>I'm doing a small automation project for a small beverage company. The instruments are not specified yet. I'm intending to specify it based on what kind of network I will use. </p> <p>So, a colleague suggest me to take a look in a ASi network, he says that it is cheap and wide used. So, what do you think? </p> http://automatoes.com/questions/16/wiring-a-rs485-modbus-rtu-network Wiring a RS485 Modbus RTU Network Mathew Lingdom 2010-03-02T21:16:48Z 2010-05-02T03:13:34Z <p>Hi experts,</p> <p>I'm having some problems for choosing a right cable for a Modbus RTU (RS485) network. I know a should use a shielded twisted pair. But it can be any kind?</p> <p>Kind Regards,</p> <p>Mathew Lingdom</p> http://automatoes.com/questions/14/is-there-any-difference-between-grounding-and-earthing-terms Is there any difference between grounding and earthing terms? Mark Braden 2010-03-01T00:49:31Z 2010-05-01T23:44:28Z <p>Is there any difference between grounding and earthing terms?</p> http://automatoes.com/questions/56/integrated-automatic-control-system-for-materials-drying-and-conditioning integrated automatic control system for materials drying and conditioning Kevin Johnson 2010-04-29T19:42:14Z 2010-04-30T14:14:59Z <p>I'm not an engineer, so don't know if I belong here, or not. We're planning a new facility and need to incorporate heat sensing, temperature monitoring and control system for drying of our input resource materials and for heat conditioning of the product materials. This will be integrated with direct and indirect solar heating systems, supplemented as need with conventional radiant heating. Any guidance for us? suggestions? consultants?</p> http://automatoes.com/questions/7/what-does-automation-mean What does Automation mean? Automatoes 2010-02-21T22:26:10Z 2010-04-30T12:21:46Z <p>What does Automation mean?</p> http://automatoes.com/questions/55/s7-400-profibus-y-link-connection S7-400 Profibus Y-Link Connection Lucius Romaom 2010-04-29T19:38:38Z 2010-04-29T19:38:38Z <p>Hi,</p> <p>Im here trying to connect the Y-link with more than 244bytes IO in a redundant automation systems by using S7 400H. Found from the documentation that Y-link is limited to 244bytes because of the profibus telegram. </p> <p>In that situation i need more Y-link, my problem is since that profibus limitation is there, does it mean that if the number of y-link I use is equal to the number of the profibus?</p> <p>Another question is if I need more than one profibus for the system, when it link to a S7 400H, is that mean I have to use the same amount as the profibus for the IM 443-5 ext?</p> http://automatoes.com/questions/39/which-are-my-options-for-a-scada-system-and-what-are-the-differences Which are my options for a SCADA system, and what are the differences? John Doe 2010-03-23T00:30:04Z 2010-04-29T16:55:32Z <p>Hi!</p> <p>Which are my options for a SCADA system, and what are the differences?</p> http://automatoes.com/questions/22/pcmcia-card-mpi-adapter-to-express-card-mpi-connection-to-siemens-plc PCMCIA Card MPI Adapter to Express Card - MPI connection to Siemens PLC Zindowe Sanham 2010-03-11T14:11:05Z 2010-04-29T11:19:13Z <p>I have a PCMCIA Card MPI adapter for connecting on Siemens Simatic PLCs. The problem is I've bought a new laptop which comes with Express Card Slot instead of PCMCIA slot.</p> <p>Is there any way a can work around this issue. Does the adaptor Express Card to PCMCIA really works in this case?</p> <p>Or should I buy the USB MPI adapter?</p> <p>Thanks for your help.</p> http://automatoes.com/questions/26/could-you-recommend-a-good-book-about-controllogix-plc-programming Could you recommend a good book about Controllogix PLC programming? Edson Alex 2010-03-12T10:57:10Z 2010-04-29T04:19:05Z <p>Could you recommend a good book about Controllogix PLC programming?</p> <p>Please.</p> http://automatoes.com/questions/38/what-is-the-difference-between-plc-and-a-microcontroller What is the difference between PLC and a Microcontroller? John Doe 2010-03-23T00:27:53Z 2010-04-29T04:12:00Z <p>What is the difference between PLC and a Microcontroller? Which one is best?</p> http://automatoes.com/questions/48/what-is-the-difference-of-a-generator-working-in-droop-or-isochronous-isoc-mode What is the difference of a generator working in Droop or Isochronous (Isoc) mode? Roby Elect 2010-04-01T21:22:17Z 2010-04-28T19:50:55Z <p>Guys,</p> <p>What is the difference of a generator working in Droop or Isochronous (Isoc) mode?</p> <p>Thanks in advance!</p> http://automatoes.com/questions/25/problems-with-autronica-autrosafe-probably-on-eac-300-board Problems with Autronica AutroSafe, probably on EAC 300 board Zindowe Sanham 2010-03-12T10:48:21Z 2010-04-24T16:24:07Z <p>I know this is not a common system. But does anyone knows how to fix an Autronica Autro Safe system. </p> <p>We are having some loop fault errors. Sometimes Autronica shows System Fault message and freezes, we checked the log and there is a RAM problem.</p> <p>The eletric tech said that they had a similar problem about a year ago, as solution the vendor exchanged the damaged EAC 300 board, as per the report. The problem is, we don't know wich is the EAC 300 board, and how to change it.</p> <p>Does anyone has a clue on this?</p> http://automatoes.com/questions/45/what-is-retrofitting What is retrofitting? Sarah Skolberg 2010-03-23T23:30:22Z 2010-03-24T00:04:14Z <p>Hi, this is my first time in Automatoes.</p> <p>My client asked me about retrofitting. From the word I can have an idea what it is, but do you have a more complete definition?</p> http://automatoes.com/questions/43/stepper-vs-servo-motors-how-can-i-choose-the-best-one-for-my-application Stepper Vs Servo Motors. How can I choose the best one for my application? John Doe 2010-03-23T04:27:25Z 2010-03-23T04:51:55Z <p>Guys,</p> <p>What is the difference between Steppers and Servo motors. What I have to look for when choosing one?</p> <p>Thanx!</p> http://automatoes.com/questions/35/adding-an-ab-powerflex-ac-drive-to-a-devicenet-network-controlled-by-a-slc-5-4-pl Adding an AB PowerFlex AC Drive to a DeviceNet network controlled by a SLC 5/4 PLC William Hughman 2010-03-16T22:05:35Z 2010-03-17T13:02:59Z <p>Gents,</p> <p>I'm a new guy to the automation engineering. What I need to do now is connect an AB (allen bradley) PowerFlex Drive to a DeviceNet network, I have a SLC 5/4 PLC.</p> <p>How can I do that?</p> http://automatoes.com/questions/12/what-are-the-options-to-industrial-wireless What are the options to Industrial Wireless? Mark Braden 2010-03-01T00:08:20Z 2010-03-15T00:38:17Z <p>Friends,</p> <p>I have big issues on choosing which industrial wireless technology to use. Does anybody has the same problems? How do you face it?</p> <p>Thanks.</p>